MINIPOWER AND STEROPOWER
UNINTERRUPTIBLE POWER SYSTEMS
The guarantee of
electrical continuity
MINIPOWER USF - UPX
Uninterruptible power system
Single-Phase 1-3 kVA
MINIPOWER USF – UPX
MINIPOWER UPH
Uninterruptible power system
Three/Single – Phase 6,5-20 kVA
MINIPOWER UPH
STEROPOWER UPG
Uninterruptible power system
Three-Phase 10-200 kVA
STEROPOWER UPG
UNINTERRUPTIBLE POWER SYSTEMS
MINIPOWER AND STEROPOWER
Minipower and Steropower are double-conversion uninterruptible power supply units ON Line, engineered to ensure highest level of protection for: high-quality machines that manage processes that, if interrupted, would result in considerable damage and/or risks; sensitive electronic equipment used in an industrial environment where, apart from power failure, temporary voltage fluctuations and strong harmonic distortions can occur.
These UPS are therefore particularly suitable for protecting and guaranteeing maximum reliability for “critical mission” devices such as: electromedical equipment, IT systems, telecommunications systems, IT networks, IT applications, industrial automation, and all critical systems in general.
IREM PROPOSAL
Minipower USF – UPX are on-line double conversion 1PH uninterruptible power supplies available in power range from 1 to 10 kVA.
The UPS of Minipower UPH series are 3PH/1PH models available in power range from 6.5 to 20 kVA, while Minipower UPG are 3PH/3PH models available in power size from 10 to 200 kVA.
Electricity supply interruptions
The Minipower and Steropower units are outstanding for the following features:
- microprocessor control to guarantee high reliability
- cost reduction thanks to high yield and various operating modes
- filtered, stabilised, reliable voltage with doubleconversion On Line technology
- high overloads (up to 150%)
- output voltage that can be personalised
- possibility to program the automatic restart when power is restored
- control of the input power factor for a sinusoidal absorbed current in phase with the line voltage with a consequential low impact on the mains
- possibility to modify the parameters via software
- battery capacity test that can be activated by the user in order to guarantee an extended life span and high reliability
- high input voltage tolerance. This characteristic is very important because it allows the user to limit use of the batteries to actual black-out situations
- parameters can be modified via software
- remote control option
- pon-off sequences can be programmed weekly
- reduced noise thanks to the use of high-frequency devices and fan speed control
- can be connected to single-phase mains (UPH models)
- option of up to 8 units in parallel for parallel redundant (UPH models and UPG 10-20 kVA).
HIGHLIGHTS
OPTIONAL GALVANIC ISOLATION
Minipower USF and UPX can be supplied with or without isolation transformer.
The UPS can be used without isolation transformer as this component does not affect the continuity function. The isolation transformer is essential when, due to transients present in the mains, it is necessary to increase the protection level to the load.
The isolation transformers used in IREM UPS are characterised by a low capacitive coupling. The resulting high attenuation allows to “condition” the mains reducing overvoltages and line noise. These disturbances, besides being more frequent that blackouts, have destructive effects for the users.
The isolation transformer is activated also in by-pass condition and allows to create a zero-potential neutral in output.
The models equipped with isolation transformer are also fitted with a thermal magnetic earth leakage circuit breaker.
OPTIMISATION OF THE BATTERIES
The high input voltage tolerance accepted makes it possible to minimise the use of the batteries, thereby increasing efficiency and duration. Moreover, in case of micro-interruption, the energy necessary is drawn from a condensing unit to further preserve the life of the batteries.
COMMUNICATION
Minipower and Steropower offer advanced communication capacity with all the most frequently used operating systems and network environments, allowing effective and intuitive unit management.
They come complete with:
- RS232 serial port;
- USB port;
- slot for communication card.
CONFORMITY WITH EEC DIRECTIVE
Minipower and Steropower are state-of-the-art equipment conforming to the most recent safety and electromagnetic compatibility regulations. More specifically they meet the requirements established by 2014/30/EU and 2014/35/EU.
UNINTERRUPTIBLE POWER SYSTEMS
OPERATING PRINCIPLE
The operating mode can be set manually by the synoptic panel or can be programmed via software.
There are 4 different operating modes:
- On Line;
- Economy Mode: selects the Interactive Line technology for cases of low-sensitivity loads. The following make it possible to increase efficiency;
- Smart Active: with this configuration, the UPS itself decides the operating mode automatically (On Line or Interactive Line) in function of the network quality;
- Rescue: the UPS works only during a black-out (only-emergency mode).
VOLTAGE STABILISERS
Ministab - Sterostab
LINE CONDITIONERS
Ministatic - Steroguard
INTEGRATED POWER SUPPLIES
AI - AO
ISOLATION TRANSFORMERS
ITT - IT
PASSIVE FILTERS FOR HARMONICS
PHF - VTF
UNINTERRUPTIBLE POWER SYSTEMS
Minipower - Steropower
VOLTAGE OPTIMISERS
Ecostab - Ecobuck