POWER QUALITY: VOLTAGE SPIKES | IREM
These are very brief pulse disturbances extremely dangerous for the most sensitive equipment since the voltage values may reach thousands of volts. They are caused by several events, like e.g. switching of high voltage lines, connection of power factor correction capacitors, lightning, disconnection of loads with high reactive powers, and also by lower power loads such as photocopy machines and air conditioners connected to the same line powering the sensitive equipment. Spikes are not detectable by means of an ordinary voltmeter due to their short duration; however they are one of the main causes of failures and malfunctions.
It is known that the phenomenon of overvoltages can be caused by the switching of large inductive or capacitive loads or in most cases by direct or indirect lightning that occurs during thunderstorms.
In particular, lightning strikes are phenomena of violent discharge that produce very high intensity currents which can reach and exceed 200 kA. Due to the enormous energy developed in short time, these events can be felt with all their destructive potential on components or systems.

IREM PROPOSAL
HIGH PROTECTION INTEGRATED POWER SUPPLIES (AO)

In order to express the highest level of performance against the effects of overvoltages with high energy content and ensure the best protection to the most sensitive and strategic users, IREM has developed a High Protection Integrated Power Supply meeting the technical requirements that describe the technical specifications of the “Absorbeur d’Ondes” (AO).

High Protection Integrated Power Supply IREM
The High Protection Integrated Power Supply combines in a single equipment various overvoltage protection strategies to provide a protected power supply with a very low residual voltage to the load. The coordinated action of a set of devices that operate selectively for switching, limiting and dissipating the energy transmitted by the overvoltage allows to offer a solution of maximum efficiency and reliability.
The functions of the protection and filter devices are integrated and energetically coordinated and ensure the highest levels of protection.
The performance of IREM High Protection Integrated Power Supplies is validated in an accredited laboratory capable of simulating the direct discharge of a lightning and measuring the residual overvoltage.
The High Protection Integrated Power Supplies are installed in series to the power supply line and upstream of the loads which, in relation to the intrinsic value or the mandatory nature of the function performed, must receive the maximum level of protection.
Among the loads with these characteristics we can consider the radio transmission systems, the control centers of rail, sea and air transport, process equipment, data processing centers, research centers, sensitive infrastructures in general and for defense.
The High Protection Integrated Power Supplies (AO) are typically composed of:

  • Input protection and disconnecting device;
  • Lightning arresters for lightning current with discharge capacity of 200kA per pole in 10/350 μs waveform;
  • Isolation transformer with high dielectric strength and electrostatic shield;
  • Protection fuses of the internal power circuit derived from the transformer;
  • Combined surge arresters with discharge capacity of 50kA per pole in 8/20 μs waveform;
  • Air wound series reactor shunted by snabber resistors;
  • Varistor surge arresters in derivation for the fine protection of common and transverse mode in waveform 1.2 / 50 μs;
  • LCR series filter for protection against high frequency noise;
  • Capacitors for absorption of residual overvoltage;
  • Output protection and disconnecting device.

Related news:

POWER QUALITY. High frequency disturbances

High frequency disturbances are caused by the sparks generated in the AC commutator motors, the “corona effect” on the high voltage lines, the igniters of luminous signs and burners, and by the magnetic fields irradiated by radio and TV stations.

read more

POWER QUALITY. Variable Harmonics

The voltage and current harmonics superimposed on the fundamental have combined effects on the equipment and devices connected to the electrical network. Some non-linear loads determine a harmonic content distributed over a very wide spectrum, therefore variable both in the harmonic order and in the intensity.

read more

POWER QUALITY. Harmonics in electric Power Supply

The harmonics in electrical systems are electrical currents or sinusoidal electrical voltages that have a frequency equal to an integer multiple of the frequency of the distribution system, called the fundamental frequency. By overlapping the Fundamental Current and the Fundamental Voltage respectively, they cause the distortion of the waveform.

read more

POWER QUALITY. Voltage imbalances

Voltage imbalances are one of the most common Power Quality problems in three-phase electrical networks. Being often overlooked, they can cause serious damage to electrical and electronic equipment.

read more

IREM

IREM SpA a socio unico

Headquarters:

Via Abegg 75
10050 Borgone Susa (TO) – ITALY

Registered office:

Via Rocciamelone 58
10050 S.Antonino di Susa (TO) – ITALY

Tel. +39 011 9648211 – Fax +39 011 9648222
E-mail: irem@irem.it

Business Register:

Torino / VAT No. IT00389630013
Fully paid-up capital: Euro 1.080.000
P.iva / CF: IT00389630013

DOWNLOAD
POWER QUALITY
NEWSLETTER CONTACT