POWER QUALITY
Energy Saving

HYDRO POWER
POWER LIGHTING


Pelton Turbine - IREM Ecowatt Hydro
PELTON TURBINE TPA - IREM HYDRO POWER
PELTON TURBINE TPA - IREM

PELTON TURBINE TPA

TPA 3-750 KW
GENERAL CHARACTERISTICS
Certifications 2006-42-CE (Machinery Directive);
2014-35-UE (LVD);
2014-30-UE (EMC)
Power range 3 – 750 kW
Head range 30-600m
Flow range 2-400 l/s
Number of nozzles 6
Flow regulation on/off valves by electrical drive for flow regulation
Generator asynchronous squirrel-cage motors, high efficiency
Generator class insulation/temp. rise F/B
Bearings of generator lifetime lubricated / with grease-gun
Temperature sensor generator windings N°3 PTC in series
Frequency 50-60 Hz
Voltage 230/400V – 277/480V, three-phase
Protection grade IP23 (protection grade of generator IP55)
Rotational speed sensor proximity 1 signal/revolution
The mechanical components in contact with water are in stainless steel
PELTON TURBINE TPA - IREM Optionals
PELTON TURBINE TPA - IREM Optionals
OPTIONALS

ON/OFF VALVES MANUALLY OPERATED
NEEDLE VALVE FOR LINEAR FLOW REGULATION DRIVEN BY ELECTRIC ACTUATOR
NEEDLE VALVE FOR LINEAR FLOW REGULATION OPERATED MANUALLY
PT100 TEMPERATURE SENSORS FOR WINDINGS GENERATOR
PT100 TEMPERATURE SENSORS FOR BEARINGS GENERATOR
VIBRATION SENSOR

POWER RANGE

IREM TURBINES POWER RANGE

A RANGE OF PRODUCTS SUITABLE IN EVERY CONDITION

STAND ALONE PLANTS: Pelton and Banki Turbines

STAND ALONE PLANTS

Pelton and Banki Turbines

GRID CONNECTED PLANTS: Pelton and Banki Turbines

GRID CONNECTED PLANTS

Pelton and Banki Turbines

AQUEDUCT INSTALLATIONS IREM Certified

AQUEDUCT INSTALLATIONS

IREM Certified